Part Number Hot Search : 
HC406 Y10EL API840N 06PBF IDT71124 13100 ZHX3403 W9425G
Product Description
Full Text Search
 

To Download LEN-0828-D12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Typical Units
Non Isolated, 12VIN, 0.8-5VOUT 28 Amp DC/DC Converters
FEATURES
Eighth brick, through hole or SMT 2-phase buck regulators for new distributed 12V power architectures 12V input (10.2-13.8V range) 0.8-2.5VOUT, 3.3VOUT @ 28A, 5VOUT @ 25A Non-isolated, fixed-frequency Synchronous-rectifier topology Efficiencies to 95% @ 25 Amps Noise as low as 25mVp-p Stable no-load operation On/Off control, trim & sense functions Input Over/Undervoltage lockout Thermal shutdown Designed to meet UL/EN/IEC60950-1 EMC compliant
PRODUCT OVERVIEW
The LEN D12 Series of non-isolated eighth bricks are ideal building blocks for emerging, on-board power-distribution schemes in which isolated 12V buses deliver power to any number of non-isolated, step-down buck regulators. LEN D12 DC/DCs accept a 12V input (10.2V to 13.8V input range) and convert it, with the highest efficiency in the smallest space, to a 0.8, 1, 1.2, 1.5, 1.8, 2, 2.5, or 3.3 Volt output fully rated at 28 Amps, or 5 Volt output at 25 Amps. LEN D12s are ideal POLPP's (point-of-use/ load power processors) and they typically require no external components. They occupy the standard eighth-brick board space (0.9" x 2.3") and come in either through-hole packages or surface-mount packages with a profile of only 0.46" (0.5" including optional heat sink). The LEN's best-in-class power density is achieved with a fully synchronous,fixedfrequency, 2-phase buck topology that delivers extremely high efficiency (95% for 5VOUT models), low noise (25mVp-p typ.), tight line/load regulation (0.25% max.), quick step response (150sec), stable no-load operation, and no output reverse conduction. The fully functional LEN's feature input over/undervoltage lockout, output overvoltage and overcurrent detection, continuous short-circuit protection, overtemperature protection, an output-voltage trim function, a remote on/off control pin, and a sense pin. High efficiency enables the LEN D12s to deliver rated output currents of 25 Amps at ambient temperatures to +65C with 200 lfm air flow without heat sink. If your new system boards call for multiple supply voltages, check out the economics of on-board 12V distributed power. If you don't need to pay for multiple isolation barriers, MPS's non-isolated 1/4 and 18 brick's will save you money.
For full details go to www.murata-ps.com/rohs
Typical topology is shown
+OUTPUT (7,9)
+INPUT (5)
+SENSE (10) COMMON (1) CURRENT SENSE COMMON (6, 8)
VCC
ON/OFF CONTROL (4)
2-PHASE PWM CONTROLLER
REFERENCE & ERROR AMP
Only one phase of two shown.
VOUT TRIM (2)
Figure 1. Simplified Schematic
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 1 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Performance Specifications and Ordering Guide
ORDERING GUIDE Output VOUT IOUT R/N (mVp-p) (Volts) (Amps) Typ. Max. 0.8 28 30 50 1 28 30 50 1.2 28 30 50 1.5 28 20 50 1.8 28 20 50 2 28 20 50 2.5 28 20 50 3.3 28 30 50 5 25 30 50 Regulation (Max.) Line Load 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.2% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% VIN Nom. (Volts) 12 12 12 12 12 12 12 12 12 Input Range (Volts) 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 10.2-13.8 IIN (mA/A) 80/2.3 80/2.8 83/3.3 89/4 92/4.7 100/5.2 130/6.4 130/7.4 130/11 Efficiency Full Load 1/2 Load Min. Typ. Typ. 79% 80% 84.5% 80% 82.5% 86% 83% 86.5% 88% 85% 88% 90% 89% 90% 91% 88% 90% 91.5% 89% 91% 93% 91% 93% 94% 92% 95% 95.5% Package (Case, Pinout) C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62 C43,C44, P62
Models LEN-0.8/28-D12 LEN-1/28-D12 LEN-1.2/28-D12 LEN-1.5/28-D12 LEN-1.8/28-D12 LEN-2/28-D12 LEN-2.5/28-D12 LEN-3.3/28-D12 LEN-5/25-D12
Typical at TA = +25C under nominal line voltage and full-load conditions, unless otherwise noted. All models are tested and specified with external 33F capacitor installed across their input and output pins. Ripple/Noise (R/N) is tested/specified over a 20MHz bandwidth. These devices have no minimum-load requirements and will regulate under no-load conditions. Regulation specifications describe the output-voltage deviation as the line voltage or load is varied from its nominal/midpoint value to either extreme.
Nominal line voltage, no-load/full-load conditions. The operating input voltage is 10.2V to 13.8V. However, 10.8VIN is required for the DC/DC to properly start up under all line, load and temperature conditions. The 10.8V potential must be maintained across the inputs until the output is up and regulating. After the output is regulating, the operating input range is 10.2V to 13.8V. There are incomplete model numbers. Please refer to the Part Number Structure when ordering.
PART NUMBER STRUCTURE
MECHANICAL SPECIFICATIONS
0.50 (12.7) W/ HEATSINK 0.46 (11.68) WO/ HEATSINK
Case C43
2.30 (58.42) 2.23 (56.64)
L EN - 1.8 / 28 - D12 M H - C
Output Configuration: L = Unipolar Low Voltage Non-Isolated Eighth Brick Nominal Output Voltage: 0.8, 1, 1.2, 1.5, 1.8, 2, 2.5, 3.3 or 5 Volts Maximum Rated Output Current in Amps RoHS-6 compliant* Heat Sink option Surface-Mount Package Blank = Through-hole package Input Voltage Range: D12 = 10.2 to 13.8 Volts (12V nominal)
SMT LEADS COPLANAR TO 0.004 (0.10)
0.150 (3.81)
0.125 (3.18)
1 6 7 8 9 10
0.035 (0.89)
0.600 (15.24)
2 3 4 5
0.90 (22.86)
Note: Not all model number combinations are available. Contact MPS.
* Contact Murata Power Solutions (Datel) for availability.
0.150 TYP. (3.81)
BOTTOM VIEW
DIMENSIONS ARE IN INCHES (MM)
0.110 (2.79)
0.50 (12.7) W/ HEATSINK 0.46 (11.68) WO/ HEATSINK
Case C44
2.23 (56.64) A
I/O Connections
Pin Function P62 1 Common 2 VOUT Trim 3 NC 4 On/Off control 5 +Input
Pin 6 7 8 9 10
Function P62 Common +Output Common +Output +Sense
0.200 MIN. (5.08)
0.122 (3.10)
PLASTIC STANDOFFS ARE RELIEVED 0.030 (0.76) IN SOLDER JOINT AREA
PINS 2-4, 10: 0.040 0.001 (1.016 0.025) PINS 1, 5-9: 0.062 0.001 (1.575 0.025)
2.00 (50.80) B
A B
1 2 3 4 5 BOTTOM VIEW
6 7 8 9 10 0.90 (22.86)
Component locations are typical and may vary with different models.
0.600 (15.24) 4 EQ. SP. @ 0.150 (3.81)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 2 of 10
LEN-D12 Models
Performance/Functional Specifications
Typical @ TA = +25C under nominal line voltage and full-load conditions unless noted. Input
Non-Isolated, 28A Eighth Brick DC/DC Converters
Absolute Maximum Ratings
Input Voltage Range Input Current: Normal Operating Conditions Inrush Transient Standby/Off Mode Output Short-Circuit Condition Input Reflected Ripple Current Input Filter Type Overvoltage Protection Reverse-Polarity Protection Undervoltage Shutdown On/Off Control
10.2-13.8 Volts (12V nominal) See Ordering Guide TBD 3.5mA 130mA 20mAp-p Capacitive (66F) 14.3 Volts None 9.4 Volts On = open or 0 to +0.4V Off = +2.8V to +VIN (<3mA)
Output
Input Voltage: Continuous or transient On/Off Control (Pin 11) Input Reverse-Polarity Protection Output Overvoltage Protection Output Current
Storage Temperature Lead Temperature (soldering, 10 sec.)
15.5 Volts +VIN None VOUT +20% Current limited. Devices can withstand sustained output short circuits without damage. -55 to +125C +300C
VOUT Accuracy (50% load) Minimum Loading Maximum Capacitive Load VOUT Trim Range
1.5% maximum No load 10,000F (low ESR, OSCON) 10% for VOUT = 1.8V +10%/-3% for VOUT 1.5V and lower (no trim for 0.8V models) See Ordering Guide 3% over line/load temperature See Ordering Guide
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied.
TECHNICAL NOTES
Ripple/Noise (20MHz BW) Total Accuracy Efficiency
Overcurrent Detection and Short-Circuit Protection: Current-Limiting Detection Point 35 Amps Short-Circuit Detection Point 98% of VOUT set SC Protection Technique Hiccup with auto recovery Short-Circuit Current TBD
Dynamic Characteristics
Return Current Paths The LEN D12 are non-isolated DC/DC converters. Their Common pins (pins 1, 6 and 8) are connected to each other internally (see Figure 1). To the extent possible (with the intent of minimizing ground loops), input return current should be directed through pin 1 (also referred to as -Input or Input Return), and output return current should be directed through pin 6 and 8 (also referred to as -Output or Output Return). Any on/off control signals applied to pin 4 (On/Off Control) should be referenced to Common (specifically pin 1). I/O Filtering and Noise Reduction All models in the LEN D12 Series are tested and specified with external 33F tantalum input and output capacitors. These capacitors are necessary to accommodate our test equipment and may not be required to achieve desired performance in your application. The LEN D12s are designed with high-quality, high-performance internal I/O caps, and will operate within spec in most applications with no additional external components. In particular, the LEN D12's input capacitors are specified for low ESR and are fully rated to handle the units' input ripple currents. Similarly, the internal output capacitors are specified for low ESR and full-range frequency response. As shown in the Performance Curves, removal of the external 33F tantalum output caps has minimal effect on output noise. In critical applications, input/output ripple/noise may be further reduced using filtering techniques, the simplest being the installation of external I/O caps. External input capacitors serve primarily as energy-storage devices. They minimize high-frequency variations in input voltage (usually caused by IR drops in conductors leading to the DC/DC) as the switching converter draws pulses of current. Input capacitors should be selected for bulk capacitance (at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The switching nature of modern DC/DCs requires that the dc input voltage source have low ac impedance and the frequencies of interest. Highly inductive source impedances can greatly affect system stability. Your specific system configuration may necessitate additional considerations.
Transient Response (25% load step) 100sec to 2% of final value Start-Up Time: VIN to VOUT and On/Off to VOUT Switching Frequency 20ms 320kHz 40kHz
Environmental
Calculated MTBF Operating Temperature: (Ambient) Without Derating (With 200 lfm) With Derating Thermal Shutdown
TBD million hours -40 to +65C (model dependent) See Derating Curves +125C
Physical
Dimensions Pin Material Weight Flamability Rating
See Mechanical Dimensions Gold-plated copper alloy with nickel underplate 0.6 ounces (17g) UL94V-0
All models are tested and specified with external 33F tantalum input and output capacitors. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33F input capacitor and a simulated source impedance of 220F and 12H. See I/O Filtering, Input Ripple Current and Output Noise for details. The On/Off Control (pin 4) is designed to be driven with open-collector logic or the application of appropriate voltages (referenced to Common, pins 1, 6 and 8). Output noise may be further reduced with the installation of additional external output filtering. See I/O Filtering and Noise Reduction. MTBF's are calculated using Telcordia SR-332(Bellcore), ground fixed, TA = +25C, full power, natural convection, TBD pcb temperature. See Performance Specifications, note 6.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 3 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Output ripple/noise (also referred to as periodic and random deviations or PARD) may be reduced below specified limits with the installation of additional external output capacitors. Output capacitors function as true filter elements and should be selected for bulk capacitance, low ESR, and appropriate frequency response. Any scope measurements of PARD should be made directly at the DC/DC output pins with scope probe ground less than 0.5" in length. All external capacitors should have appropriate voltage ratings and be located as close to the converters as possible. Temperature variations for all relevant parameters should be taken into consideration. The most effective combination of external I/O capacitors will be a function of your line voltage and source impedance, as well as your particular load and layout conditions. Our Applications Engineers can recommend potential solutions and discuss the possibility of our modifying a given device's internal filtering to meet your specific requirements. Contact our Applications Engineering Group for additional details. Input Fusing Most applications and or safety agencies require the installation of fuses at the inputs of power conversion components. LEN D12 Series DC/DC converters are not internally fused. Therefore, input fusing is mandatory for safety reasons, and safety agencies require a time delay fuse with a value no greater than 40 Amps, which should be installed within the ungrounded input path to the converter. As a rule of thumb however, we recommend to use a normal-blow or slow-blow fuse with a typical value of about twice the maximum input current, calculated at low line with the converters minimum efficiency. Safety Considerations LEN D12's are non-isolated DC/DC converters. In general, all DC/DC's must be installed, including considerations for I/O voltages and spacing/separation requirements, in compliance with relevant safety-agency specifications (usually UL/IEC/EN60950-1). In particular, for a non-isolated converter's output voltage to meet SELV (safety extra low voltage) requirements, its input must be SELV compliant. If the output needs to be ELV (extra low voltage), the input must be ELV. Start-Up Time The VIN to VOUT Start-Up Time is the interval between the time at which a ramping input voltage crosses the lower limit of the specified input voltage range (10.2 Volts) and the fully loaded output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input capacitance, and the slew rate and final value of the input voltage as it appears to the converter. The On/Off to VOUT Start-Up Time assumes the converter is turned off via the On/Off Control with the nominal input voltage already applied to the converter. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltage enters and remains within its specified accuracy band. See Typical Performance Curves. Remote Sense LEN D12 Series DC/DC converters offer an output sense function on pin 10. The sense function enables point-of-use regulation for overcoming moderate IR drops in conductors and/or cabling. Since these are non-isolated devices whose inputs and outputs usually share the same ground plane, sense is provided only for the +Output. The remote sense line is part of the feedback control loop regulating the DC/DC converter's output. The sense line carries very little current and consequently requires a minimal cross-sectional-area conductor. As such, it is not a low-impedance point and must be treated with care in layout and cabling. Sense lines should be run adjacent to signals (preferably ground), and in cable and/or discrete-wiring applications, twisted-pair or similar techniques should be used. To prevent high frequency voltage differences between VOUT and Sense, we recommend installation of a 1000pF capacitor close to the converter. The sense function is capable of compensating for voltage drops between the +Output and +Sense pins that do not exceed 10% of VOUT. [VOUT(+) - Common] - [Sense(+) - Common] 10%VOUT Power derating (output current limiting) is based upon maximum output current and voltage at the converter's output pins. Use of trim and sense functions can cause the output voltage to increase, thereby increasing output power beyond the converter's specified rating. Therefore: (VOUT at pins) x (IOUT) rated output power The internal 10.5 resistor between +Sense and +Output (see Figure 1) serves to protect the sense function by limiting the output current flowing through the sense line if the main output is disconnected. It also prevents output voltage runaway if the sense connection is disconnected. Note: If devices have the +Sense pin (pin 10) installed (no part-number suffix) and the sense function is not used for remote regulation, +Sense (pin 10) must be tied to +Output (pin 7, 9) at the DC/DC converter pins. On/Off Control The On/Off Control pin may be used for remote on/off operation. LEN D12 Series DC/DC converters are designed so that they are enabled when the control pin is left open (or pulled low to 0 to +0.4V) and disabled when the control pin is pulled high (+2.8V to +VIN). As shown in Figure 2, all models have an internal 20k pull-down resistor to Common (ground).
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 4 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
+INPUT 2.5V Optional Pullup 10k
ON/OFF CONTROL
+ - 20k
Small Signal Transistor
COMMON
Output Overvoltage Protection The LEN D12 Series output voltage is monitored. If the output voltage rises to a level, which could be damaging to the load, the internal sensing circuitry will power down the PWM controller causing the output voltage to decrease. Following a time-out period the PWM will restart, causing the output voltage to ramp to its appropriate value. If the fault condition persists, and the output voltage again climbs to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode. Output Overcurrent Detection Overloading the power converter's output for an extended time will invariably cause internal component temperatures to exceed their maximum ratings and eventually lead to component failure. High-current-carrying components such as inductors, FET's and diodes are at the highest risk. LEN D12 Series DC/DC converters incorporate an output overcurrent detection and shutdown function that serves to protect both the power converter and its load. If the output current exceeds it maximum rating by typically 40% (35 Amps) or if the output voltage drops to less than 98% of it original value, the LEN D12's internal overcurrent-detection circuitry immediately turns off the converter, which then goes into a "hiccup" mode. While hiccupping, the converter will continuously attempt to restart itself, go into overcurrent, and then shut down. Under these conditions, both the average output current and the average input current will be kept extremely low. Once the output short is removed, the converter will automatically restart itself. Output Voltage Trimming Allowable trim ranges for models 1.8VOUT are 10%, and for models 1.5VOUT and lower +10%/-3% (no trim for 0.8V models). Trimming is accomplished with either a trimpot or a single fixed resistor. The trimpot should be connected between +Output and Common with its wiper connected to the Trim pin as shown in Figure 4.
ON/OFF pin open: Logic Low = DC/DC converter On ON/OFF pin >2.8V: Logic High = DC/DC converter Off
Figure 2. Driving the On/Off Control Pin
Dynamic control of the on/off function is best accomplished with a mechanical relay or open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current when activated and withstand appropriate voltage when deactivated. The on/off control can be driven using a circuit comparable to that shown in Figure 2. Leaving the On/Off control pin open or applying a voltage between 0V and +0.4V will turn on the converter. Applied voltages between +2.8V and +VIN will disable the converter. Power-up Sequencing If a controlled start-up of one or more LEN D12 Series DC/DC converters is required, or if several output voltages need to be powered-up in a given sequence, the On/Off control pin can be pulled high to +VIN with an external 5.6k restistor. While input voltage and/or other converters are ramping up, the control pin is pulled high and the converter remains disabled. To enable the output voltage, the control pin needs to be pulled low in the configuration shown in Figure 3.
+INPUT 2.5V 5.6k ON/OFF CONTROL + - 20k COMMON
External Input Open: On/Off pin High = DC/DC converter Off External Input Low: On/Off pin Low = DC/DC converter On
Figure 4. Trim Connections Using a Trimpot
Figure 3. Driving The Power-Up With An External Pull-up Resistor
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 5 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
A trimpot can be used to determine the value of a single fixed resistor which can then be connected, as shown in Figure 5, between the Trim pin and +Output to trim down the output voltage, or between the Trim pin and Common to trim up the output voltage. Fixed resistors should have absolute TCR's less than 100ppm/C to ensure stability.
+OUTPUT +INPUT TRIM COMMON COMMON Trim Up Trim Down LOAD Note: Install either a fixed trim-up resistor or a fixed trim-down resistor depending upon desired output voltage.
Output Reverse Conduction Many DC/DCs using synchronous rectification suffer from Output Reverse Conduction. If those devices have a voltage applied across their output before a voltage is applied to their input (this typically occurs when another power supply starts before them in a power-sequenced application), they will either fail to start or self destruct. In both cases, the cause is the "freewheeling" or "catch" FET biasing itself on and effectively becoming a short circuit. LEN D12 DC/DC converters do not suffer from Output Reverse Conduction. They employ proprietary gate drive circuitry that makes them immune to applied output voltages.
Figure 5. Trim Connections Using Fixed Resistors
The equations below can be used as starting points for selecting specific trim resistor values. Recall, untrimmed devices are guaranteed to be 1% accurate. Adjustment beyond the specified adjustment range is not recommended.
Trim Equations RT DOWN (k) = 0.5(VO - 0.8) VO NOM - VO -X RT UP (k) = X = 0.261 X = 0.750 X = 1.24 X = 1.62 X = 1.62 0.4 VO - VO NOM -X
LEN-1/28-D12: LEN-1.2/28-D12: LEN-1.5/28-D12: LEN-1.8/28-D12: LEN-2/28-D12:
LEN-2.5/28-D12 RT DOWN (k) = 1.18(VO - 0.8) VO NOM - VO 7.5(VO - 0.8) VO NOM - VO - 3.09 RT UP (k) = 0.944 VO - VO NOM 6 VO - VO NOM - 3.09
RT DOWN (k) =
-X
RT UP (k) =
-X
LEN-3.3/28-D12: X = 14.3 LEN-5/25-D12: X = 9.53 Note: LEN-0.8/28-D12 is not trimmable.
Note: Resistor values are in k. Accuracy of adjustment is subject to tolerances of resistors and factory-adjusted, initial output accuracy. VO = desired output voltage. VOMON = nominal output voltage.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 6 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Typical Performance Curves
LEN-0.8/28-D12 Efficiency vs. Line Voltage and Load Current 92.5 90 87.5 Efficiency (%) 85 82.5 80 77.5 75 72.5 2.5
VIN = 10.8V VIN = 12V VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps) LEN-1/28-D12 Efficiency vs. Line Voltage and Load Current 92.5 90 87.5 Efficiency (%) 85 82.5 80 77.5
VIN = 10.8V VIN = 12V VIN = 13.2V
75 72.5 2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps) LEN-1.2/28-D12 Efficiency vs. Line Voltage and Load Current 92.5 90 87.5 Efficiency (%) 85
VIN = 10.8V
82.5
VIN = 12V
80 77.5 75 72.5 2.5
VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 7 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Typical Performance Curves
LEN-1.5/28-D12 Efficiency vs. Line Voltage and Load Current 92.5 90 87.5 Efficiency (%) 85 82.5 80 77.5 75 72.5 2.5
VIN = 10.8V VIN = 12V VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps) LEN-1.8/28-D12 Efficiency vs. Line Voltage and Load Current 92.5 90 87.5
VIN = 10.8V
Efficiency (%) 85
VIN = 12V
82.5 80 77.5 75 72.5 2.5
VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps) LEN-2/28-D12 Efficiency vs. Line Voltage and Load Current 97.5 95 92.5 Efficiency (%) 90 87.5 85 82.5
VIN = 10.8V VIN = 12V VIN = 13.2V
80 77.5 2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 8 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Typical Performance Curves
LEN-2.5/28-D12 Efficiency vs. Line Voltage and Load Current 97.5 95 92.5 Efficiency (%) 90 87.5 85 82.5 80 77.5 2.5
VIN = 10.8V VIN = 12V VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps)
LEN-3.3/28-D12 Efficiency vs. Line Voltage and Load Current 97.5 95
LEN-3.3/28-D12 Maximum Current Temperature Derating VIN = 12V (air flow from pin 1 to pin 5)
400 lfm W/ HEAT SINK
Output Current (Amps)
92.5 Efficiency (%) 90 87.5 85 82.5 80 77.5 2.5
200 lfm W/ HEAT SINK 100 lfm W/ HEAT SINK
VIN = 10.8V VIN = 12V VIN = 13.2V
400 lfm WO/ HEAT SINK 200 lfm WO/ HEAT SINK 100 lfm WO/ HEAT SINK
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
Load Current (Amps)
Ambient Temperature (C)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 9 of 10
LEN-D12 Models
Non-Isolated, 28A Eighth Brick DC/DC Converters
Typical Performance Curves
LEN-5/25-D12 Efficiency vs. Line Voltage and Load Current 97.5 95 92.5 Efficiency (%) 90 87.5 85 82.5 80 77.5 2.5
VIN = 10.8V VIN = 12V VIN = 13.2V
5
7.5
10
12.5
15
17.5
20
22.5
25
Load Current (Amps)
USA: Tucson (AZ), Tel: (800) 547 2537, email: sales@murata-ps.com Canada: UK: France: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Germany: Munchen, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Murato Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com
ISO 9001 REGISTERED
Japan:
email: sales@murata-ps.com
DS-0532 12/20/07
China:
(c) 2007 Murata Power Solutions, Inc. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LEN D12 Models.B01 Page 10 of 10


▲Up To Search▲   

 
Price & Availability of LEN-0828-D12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X